ITL SOFTWARE · TECHNICAL EVIDENCE · v0.11.0

Verifiable evidence. A bounded OEM pilot.

A vendor-neutral technical summary of the non-clinical POC platform with a bounded OEM integration proposal. Implemented evidence and pilot hypotheses are deliberately separated.

Independent ITL technical evaluation proposal. No medical clearance, hardware qualification or general OEM compatibility claim.

01 / PUBLIC EVIDENCE

Evidence status with explicit gaps

Based on the versioned v0.11.0 QA report. The public manifest indexes evidence status; it does not replace full logs, executable test artifacts or on-device acceptance.

IDAreaStatusEvidence / boundary
POC-E01C++20 CoreHost tested40/40 CTest groups GNU Debug (grouped runs)
docs/QA_EVIDENCE.md
POC-E02Independent C++ toolchainHost tested40/40 CTest groups Clang Release (grouped runs)
docs/QA_EVIDENCE.md
POC-E03ASan/UBSanPartially tested6/6 selected groups; not full sanitizer-suite qualification
docs/QA_EVIDENCE.md
POC-E04Python OEM POC4Host testedC++/Python independent IPC scenarios and negative cases
tests/oem_cross_language.py
POC-E05Rust OEM POC4Source onlySources and tests included; Rust compiler unavailable in recorded v0.11.0 QA
sdk/rust/ and tests/oem_rust_integration.py
POC-E06ARM64 VMNot testedNo ARM64 VM acceptance evidence
docs/ARM64_ACCEPTANCE.md
POC-E07CAN / PREEMPT_RT / HILNot testedNo physical CAN driver, jitter/deadline measurements or HIL acceptance
docs/ARM64_ACCEPTANCE.md
POC-E08Medical/IVDRNot qualifiedNo medical instrument qualification, clinical validation or device conformity claim
docs/QUALITY_AND_REGULATORY.md
Public JSON evidence manifest

Contains QA statuses, source references, baseline version and source-archive SHA-256 — without source code, secrets or patient data.

JSON / v0.11.0

Manifest SHA-256 1315ac0e4c32de99246f182a6bf4295036f020d63aaae14f3897777f231b215a

Not automatically updated: new results require independent QA and review before a new evidence baseline is published.

02 / NON-INVASIVE INTEGRATION

Integration with existing OEM systems: complement, not replace

The following integration approaches are vendor-neutral reference options. Interfaces, deployment and safety ownership must be agreed with each OEM before a pilot.

Embedded Linux / Debian

Example OEM environment using Debian-based embedded Linux; target system and policies are defined for each pilot.

ITL integration hypothesis

Separate non-root service, explicit resource boundaries and packaged workers. No compatibility with any specific OEM image has been demonstrated.

Virtual Instrument / HIL

Existing or planned OEM virtual instruments and hardware-in-the-loop benches; interfaces are project-specific.

ITL integration hypothesis

POC4 is a testable adapter boundary. No plug-and-play compatibility with unknown OEM simulators is assumed.

Embedded Rust / C++

C++20 workflow core and Rust/Python adapters as alternative integration approaches.

ITL integration hypothesis

C++ core and Python adapter host-tested; Rust worker source available, runtime acceptance pending.

Architecture note: these integration options are vendor-neutral; suitability must be demonstrated against a specific OEM test system.

03 / PILOT ACCEPTANCE PLAN

Seven verifiable pilot gates

Proposed criteria, not an OEM-approved device specification. Metric thresholds, reference hardware, protocols and safety ownership must be agreed before the pilot.

A01

ARM64 native build

OPEN

Build C++ and Rust on ARM64 Linux; record toolchain versions and artifact hashes.

Pass criterion: Build and unit tests PASS; architecture verified

A02

POC4 / C++ ↔ Rust

OPEN

Exercise 14 operations and invalid frames, dead worker, timeouts, identity and restart.

Pass criterion: No unintended execution; all negative cases reproduced

A03

Debian / systemd

OPEN

Run separate service on agreed Linux test target with minimum privilege.

Pass criterion: Cgroup/recovery, permissions and journal documented

A04

PREEMPT_RT / timing

OPEN

Measure under agreed load profile; define timing budgets with OEM before testing.

Pass criterion: p95/p99, worst-case and jitter within agreed bounds

A05

CAN / Hardware Boundary

OPEN

Versioned CAN/device protocol, unknown outcomes and no unsafe retries.

Pass criterion: Fault injection, reconciliation and safe-stop lab verified

A06

HIL / Non-clinical

OPEN

Water/reference solutions, defined pump and sensor failure paths, independent emergency stop.

Pass criterion: Physical outputs safe under process/power failure

A07

QA / Traceability

OPEN

Requirements → risks → tests → evidence; track findings in review.

Pass criterion: Reviewed evidence matrix and go/no-go, not regulatory clearance

OEM FEASIBILITY CONVERSATION

Agree technical boundaries before the pilot

Start with target platform, device interface, timing budget and required evidence. Do not submit confidential OEM materials or patient information through the public form.

The existing ITL form issues a reference on mail-transport acceptance; this does not prove inbox delivery.
Request evaluation